ABOUT Teplos-Top
We offer professional liquid heat-insulation coating - Teplos Top to companies engaged in apartment reconstruction and civil engineering to solve problems with thermal insulation of walls, roof and basements, non-residential premises, pipelines and various tanks.
Teplos Top has unique properties supporting thermal insulation of spaces, basements, tanks, pipelines. It can be also used instead of a thick layer of standard insulation. After drying Teplos Top forms THIN, STRONG, ELASTIC, DURABLE, NOT TOXIC heat-insulation coating.
Heat-insulation coating is available in more than 500 colours supporting designs of facades and interiors in different colours.
Physical and mechanical properties of Teplos-Top
Index | Unit of measure | Value |
Specific weight | g/cm3 | 0.82 |
Adhesion | % | 100 |
Tension strength | kg/cm2 | 4.8 |
Heat-conductivity factor | W/(m?K) | 0.01 |
Heat resistance | °Ñ | -60/+260 |
Elongation | % | 65 |
Diagram – schema.jpg
«Scope»
Professional heat-insulation coating is recommended to use in the following cases:
For heat insulating of structures and buildings erected by obsolete design and not meeting to SNiP of 2003 regarding heat insulation of structures and buildings.
For heat insulating of cold-penetration walls sandwich- panels.
As heat-reflective insulation of pipelines of hot and cold water supply.
As heat –insulating protection of condensate.
As fungus proofing coating.
For heat insulating of glazed balconies.
In new building, when keeping of internal spaces in maximum volume is important as well as outside structure gauges.
At assembly of ventilated facades as heat insulation.
For heat insulating of ventilation systems.
For heat insulating of roofs, particularly of ones with large area.
At repairing and sealing of panel joints with further heat insulating.
For heat insulating of basements.
For heat insulating of basement storeys and semi-basement storeys, including store spaces.
For heat insulating of tanks.
For heat insulating of river and sea ships.
For heat insulating of electric substations.
For heat insulating of cold-penetration areas of rail way cars.
For heat insulating of motor-vehicles.
For heat insulating of motor-vehicle trailers.
For heat insulating of animal farms.
For heat insulating of containers.
For heat insulating of garages.
For tunnel heat insulating.
For heat insulating of gas compressor units.
For heat insulating and fungus protecting of bread-making plants.
For heat insulating and fungus protecting of brewhouses.
At contraction of quick erected structures.
At contraction and heat insulating of henhouses.
«Direction for Use»
Direction for Application of Heat-Insulation Coating “Teplos Top”
(Multipurpose)
“Teplos Top” is water soluble paint with special additives giving it pronounced heat reflecting and heat saving effect.
Application can be carried out on surfaces with temperature in range + 7° Ñ up to + 150° Ñ. Recommended temperature for product transportation and storage is not lower +5°Ñ.
Preparation of Insulation Coating
“Teplos Top” does not require special preparation, immediately before application it shall be stirred thoroughly.
· Remove lid from the bucket. Break formed crust by dipping and lifting of flat blade with care in the centre on the bucket and along its walls in order to cover the crust with liquid.
· Going on vertical movement of the blade, dip stiffened part of the product into the liquid, switch on the drill with mixing piece and start stirring of the bucket content slowly, mixing cluster with the liquid (to prevent rotation of the bucket, hold it by feet and knees).
· Go on stirring till full dissolution of the crust and formation of homogeneous, <creamy> mixture without clusters and clots.
· Transfer mixed product to clean bucket through filter with mesh diameter in range (0.5-1.0 mm), remove residual clots to prevent spray clogging.
· Wet film thickness for single layer of “Teplos Top” –is not above 0.4 mm. At multilayer application dry each subsequent layer at least 6 hours at temperature 200Ñ.
ATTENTION!
Do not use high-speed stirring to prevent lost of heat saving properties. When drill is used for stirring speed of mixing shall not be higher 300 rpm.
Surface Preparation
It is smoothly applied on all types of surfaces: metals, wood, plastics, glass, concrete, brick etc. The surface shall be free of moisture and oil.
Equipment
“Teplos-Top” can be applied on surfaces by sprayers and brushes.
Sprayer Preparation for Operation
· Airless sprayer: preliminary supply clean water through the sprayer (about 2 litres), then transfer the hose into bucket with “Teplos-Top”. When water is spent and “Teplos-Top” is started to be supplied, direct the sprayer into bucket with “Teplos-Top” (use the nozzle with diameter of 0.5 – 0.8 mm). Both product and equipment are ready for application.
Wet film thickness is max 0.4 mm. Apply subsequent layers when the previous ones are dried up (refer to para. 1.5).
Product Application
Before product application on any surface, apply the primer coat and dry it up (min. 1 hour at room temperature).
Hot Surfaces
When product is to be applied on hot surfaces with temperature of 80°Ñ and higher, use more liquid primer (per 1 kg of product - 250 g of water).
Inspection of Applied Coating Thickness
Applied coating thickness shall be inspected when dried up completely:
Safety Requirements
· When using the product, follow safety requirements according to SNiP 111-4-80, SanPin 6027À-91, GOST 20010, GOST 12,04,013, GOST 27575, and GOST 27574.
«Contacts»
Russia, 117036, Moscow,
Profsoyuznaya St. 5/9, 2nd Entrance Door
Phone: +7-499-530-0372, +7-499-530-0382
e-mail: teplostop@gmail.com
Russia, 105264, Moscow,
5th Parkovaya St., 46
Phone: +7-495-965-3319, +7-495-965-3338, +7-495-965-3346
e-mail: hvlp@hvlp.ru